3 Follow the procedure listed in After working inside your system.
Drives
Drives are supplied in hot swappable drive carriers that t in the drive slots.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the storage
controller card to ensure that the host adapter is congured correctly.
CAUTION: Do not turn o or restart your system while a drive is being formatted. Doing so can cause a drive
failure.
When you format a drive, allow enough time for the formatting to complete. Be aware that high-capacity drives can take a long time to
format.
Removing a drive blank
The procedure for removing 2.5 inch and 3.5 inch drive blanks is identical.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If installed, remove the front bezel.
CAUTION
: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release button, and slide the drive blank out of the drive slot.
Figure 39. Removing a drive blank
Next steps
1 Follow the procedure listed in After working inside your system.
2 Install a drive or a drive blank.
3 If applicable, replace the front bezel.
Installing and removing system components
53