Removing the hard drive backplane
Prerequisites
CAUTION: To prevent damage to the drives and backplane, remove the hard drives from the system before
removing the backplane.
CAUTION: Note the number of each hard drive and temporarily label them before you remove the hard drive so
that you can replace them in the same location.
NOTE: The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the air shroud.
4. Remove the backplane cover.
5. Remove all hard drives from the front bay.
6. Disconnect all the cables from the backplane.
Steps
Press the release tabs and lift the backplane to disengage the backplane from the hooks on the system.
NOTE:
If your backplane has an expander board, the loosen the screws on the expander board before you remove the
backplane.
Installing and removing system components 99