Figure 65. Configuration 13: 24 x 2.5-inch (SAS4/SATA) Dual Controller with fPERC 11
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 81. 24 x 2.5-inch (SAS4/SATA) Dual Controller with fPERC 11
Order From To
1 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller connector)
2 CTRL_SRC_SA1 (Adapter PERC controller
connector)
BP_DST_SB1 (backplane signal connector)
3 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power connector)
4 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
5 CTRL_SRC_SA1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)