EasyManua.ls Logo

Dell PowerEdge R860 - Page 106

Dell PowerEdge R860
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 66. Configuration 14: 24 x 2.5-inch (SAS4/SATA) + 2 x 2.5-inch (SAS/SATA) Dual controller with fPERC 11
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 82. 24 x 2.5-inch (SAS4/SATA) + 2 x 2.5-inch (SAS/SATA) Dual controller with fPERC 11
Order From To
1 CTRL_SRC_SB1 (fPERC controller connector) BP_DST_SB1 (backplane signal
connector)
2 SL4_CPU1_PA3 (signal connector on system
board)
CTRL_DST_PA1 (fPERC controller
connector)
3 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power
connector)
4 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power
connector)
5 SIG_PWR_0/BATT2 (system board power
connector)
BP _PWR_1 (Rear backplane power
connector)
6 CTRL_SRC_SA1 (Adapter PERC controller
connector)
BP_DST_SA1 and BP_DST_SB1 (Rear
backplane signal connector)
7 CTRL_SRC_SA1 (fPERC controller connector) BP_DST_SA1 (backplane signal
connector)
106 Installing and removing system components