EasyManua.ls Logo

Dell PowerProtect DD6900 - Replace a Power Supply; Identify Failed Power Supply

Dell PowerProtect DD6900
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Replace a Power Supply
T
he system contains two power supplies in the rear of the chassis.
Complete the following procedure to replace a failed power supply.
This CRU can be performed with the system powered on.
Topics:
Identify a failed power supply
Remove a power supply
Install the power supply unit
Verify the replacement power supply
Restore the HA configuration
Identify a failed power supply
Prerequisites
Establish a connection to the system as described in Establish a serial management connection to the PowerProtect system on
page 14.
About this task
Complete the following steps to identify the failed power supply.
Steps
1. Check the LED on the affected power supply unit. The power supply handle functions as the LED.
NOTE:
If a power supply unit is found to be faulted, the LED blinks amber.
2. E
nter the alerts show current command (or alerts show current-detailed) to display messages indicating
power supply failure. A sample output is shown.
NOTE: The sample output below only includes the alert object and alert message. It does not include the columns for
the alert ID, post time, severity, and alert class which are part of the actual output.
5
Replace a Power Supply 31

Table of Contents

Related product manuals