EasyManua.ls Logo

Dell PowerStore 1000 - Power down the Node; Remove an Embedded Module

Dell PowerStore 1000
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 6. Embedded module LEDs (continued)
LED Location State Description
Blue Node in Degraded Mode.
Amber or blue
blinking
System is booting.
Blue and amber
alternating (green
for 3 seconds)
System uninitialized. A management IP
address has not been assigned.
Blue and amber
alternating at one
second intervals
Node in Service Mode.
Port link Green Link up with high speed.
Amber Link up with degraded speed.
Off Link down.
Ethernet port activity Amber blinking Port activity.
Off No port activity.
Ethernet port link Green Link established.
Off No link established.
2-port 100GbE card port link Green Link established.
Off No link established.
Embedded module fault Amber Embedded module has faulted.
Off No fault has occurred, normal operation.
2-port 100GbE card port activity Green blinking Port activity.
Off No port activity.
Power down the node
Power down the node as described in Power control procedures.
Remove an embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts
the system cache.
2. Push the orange tab on the embedded module to release the lever.
76
Base enclosure service procedures

Table of Contents