Table 35. 2U12, 2U24, and 5U84 enclosure weights (continued)
CRU/component 2U12 (kg/lb) 2U24 (kg/lb) 5U84 (kg/lb)
EBOD enclosure (fully populated with
modules: maximum weight)
28/62 25/55 130/287
NOTE:
Weights shown are nominal, and subject to variances.
Weights may vary due to different controller modules, IOMs, and power supplies; and differing calibrations between
scales.
Weights may also vary due to the number and type of disk drives (SAS or SSD) installed.
Environmental requirements
Table 36. Ambient temperature and humidity
Specification Temperature range Relative humidity Max. Wet Bulb
Operating
RBOD: 5ºC to 35ºC (41ºF to
95ºF)
EBOD: 5ºC to 40ºC (41ºF to
104ºF)
20% to 80% non-condensing 28ºC
Non-operating (shipping) -40ºC to +70ºC (-40ºF to +158ºF) 5% to 100% non-precipitating 29ºC
Table 37. Additional environmental requirements
Specification Measurement/description
Airflow
System must be operated with low pressure rear exhaust installation.
Back pressure created by rack doors and obstacles not to exceed 5Pa (~0.5
mm H
2
O)
Altitude, operating
2U enclosures: 0 to 3,000 meters (0 to 10,000 feet)
Maximum operating temperature is de-rated by 5ºC above 2,133 meters (7,000
feet)
5U84 enclosures: -100 to 3,000 meters (-330 to 10,000 feet)
Maximum operating temperature is de-rated by 1ºC above 900 meters (3,000
feet)
Altitude, non-operating -100 to 12,192 meters (-330 to 40,000 feet)
Shock, operating 5.0 g, 10 ms, ½ sine pulses, Y-axis
Shock, non-operating 2U enclosures: 30.0 g, 10 ms, ½ sine pulses
5U84 enclosures: 30.0 g, 10 ms, ½ sine pulses (Z-axis); 20.0 g, 10 ms, ½ sine pulses
(X- and Y-axes)
Vibration, operating 0.21 G
rms
5 Hz to 500 Hz random
Vibration, non-operating 1.04 G
rms
2 Hz to 200 Hz random
Vibration, relocation 0.3 G
rms
2 Hz to 200 Hz 0.4 decades per minute
Acoustics Operating sound power
2U enclosures: L
WAd
6.6 Bels (re 1 pW) @ 23ºC
5U84 enclosures: L
WAd
8.0 Bels (re 1 pW) @ 23ºC
Orientation and mounting 19" rack mount (2 EIA units; 5 EIA units)