Configure the Top Storage Controller
Configure the top storage controller (storage controller 1) with the information provided in the pre-
installation documents.
Prerequisites
Create a serial connection from a computer to the storage controller, as described in Establish a Serial
Connection to the Top Storage Controller.
About this task
Configure the top storage controller with the lower HSN, IP addresses for the Ethernet management
interface (eth0) and baseboard management controller (BMC), one or more DNS servers, and the domain
name.
Figure 84. Storage Controllers
1. Top storage controller (storage controller 1) 2. Bottom storage controller (storage controller
2)
Steps
1. In the terminal emulator, press Enter several times to initiate the connection to the storage
controller. The terminal emulator displays the prompt <SafeMode> sn0> to indicate that the
storage controller is in Safe Mode.
2. Run the following command to enter the shellacess developer mode.
shellaccess developer
3. Run the following command to display the prejoin configuration information that must be specified.
platform prejoin show
Example:
<SafeMode> sn0> platform prejoin show
****************************************************************
Prejoin configuration:
System (License) Serial Number: 0
Item Value
------------ --------------------------------
Canister 0
HSN 0
eth0 IPv4 0.0.0.0/32
eth0 IPv6 ::/128
eth1 IPv4 169.254.1.101/30
eth1 IPv6 ::/128
gateway IPv4 0.0.0.0
gateway IPv6 ::
Domain
DNS Server 0 0.0.0.0
Set up Storage Center Software