EasyManua.ls Logo

Dell SC4020 - Add Controller Page

Dell SC4020
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 MB: Appropriate for systems that use a large amount of disk space with infrequent Replays
(such as video streaming).
CAUTION: When considering using either the 512 KB or 4 MB datapage settings, contact
Dell Technical Support for advice on balancing resources and to understand the impact
on performance.
d. To configure the disk folder to use RAID 0, select the Prepare Disk Folder for non-redundant
storage checkbox. Non-redundant storage does not protect data in the event of a disk failure.
Select this option only for data that is backed up some other way.
e. Click Continue.
5. Click Create Now. The disk folder is created and the Add Controller page opens.
Add Controller Page
If the storage controllers are configured with the correct prejoin information, the Storage Center Startup
Wizard automatically joins the storage controllers
1. Storage Center joins the bottom storage controller to the top storage controller. It then restarts the
bottom storage controller.
Figure 94. Waiting for the Bottom Storage Controller to Restart
2. Storage Center loads configuration information onto the bottom storage controller.
Figure 95. Loading Configuration Information on the Bottom Storage Controller
3. Storage Center rebalances the local ports on both storage controllers.
114
Set up Storage Center Software

Table of Contents

Other manuals for Dell SC4020

Related product manuals