Figure 120. iSCSI Ports Tab in Virtual Ports Mode
2. Create a fault domain for each pair of redundant iSCSI ports.
a. Click Edit Fault Domains. The wizard displays a list of the currently defined fault domains.
b. Click Create Fault Domain. A dialog box opens.
c. In the Name field, type a name for the fault domain.
d. From the Type drop-down menu, select iSCSI.
e. (Optional) In the Notes field, type a description of the fault domain.
f. Click Continue. The dialog box displays a summary.
g. Click Create Now.
h. Repeat the previous steps to create additional fault domains as needed.
i. When you are finished creating fault domains, click Return. The iSCSI tab opens.
3. Configure the iSCSI front-end ports numbered Slot 1/Port 1 and Slot 2/Port 2 on each storage
controller..
a. Set the Purpose field to Front End.
b. Set the Fault Domain field to the appropriate fault domain.
c. (Optional) Type a descriptive name in the User Alias field.
134
Set up Storage Center Software