c. (Optional) Type a descriptive name in the User Alias field.
Figure 123. Configure Embedded iSCSI Ports
6. (Optional) Change the preferred physical port for one or more virtual ports.
a. Click Edit Virtual Ports. The wizard displays a list of virtual ports.
b. For each virtual port that you want to modify, select the preferred physical port in the Preferred
Physical Port
field.
c. When you are finished, click Apply Changes. The iSCSI tab opens.
7. If you do not plan to use an iSCSI port, make sure that the port is not configured.
a. Set the Purpose field to Unknown.
b. Set the Fault Domain field to <none>.
c. (Optional) Type a descriptive name in the User Alias field.
Configure Front-End SAS Ports
The front-end SAS ports of an SC4020 storage system cannot be configured using the Storage Center
Startup Wizard.
To configure the front-end SAS ports of an SC4020 storage system, see the Dell SC4020 Storage System
Front-End SAS Configuration Tech Note.
Configure Back-End SAS Ports
Use the SAS tab to configure the back-end SAS ports.
1. Click the SAS tab.
136
Set up Storage Center Software