Item Control/Feature Icon Description
Blinking amber and yellow: Beacon
All blinking (simultaneous): Firmware initialized
All blinking (alternating): Firmware fault
15 Mini-SAS port B (Slot 2/
Port 2)
Back-end expansion port B
16 Mini-SAS port A (Slot 2/
Port 1)
Back-end expansion port A
SC4020 Storage System Storage Controller with iSCSI Front-End Ports
The following figure shows the features and indicators on a storage controller with iSCSI front-end ports.
Figure 11. SC4020 Storage System Storage Controller with Two 10 GbE iSCSI Front-End Ports
Item Control/Feature Icon Description
1 Battery status indicator
Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat
Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is
charging
Steady green: Battery is ready
2 Battery fault indicator
Off: No faults
Blinking amber: Correctable fault detected
Steady amber: Uncorrectable fault detected; replace battery
3 MGMT port (Slot 3/Port
1)
Ethernet/iSCSI port that is typically used for storage system
management and access to the BMC
NOTE: The MGMT port can be used as an iSCSI port for
replication to another Storage Center or as a front-end
iSCSI port for connections to host servers.
4 REPL port (Slot 3/Port 2) Ethernet/iSCSI port that is typically used for replication to
another Storage Center
NOTE: The REPL port can be used as a front-end iSCSI port
for connections to host servers.
5 SAS activity indicators There are four SAS PHYs per SAS port.
Off: SAS PHY is not connected
Steady green: SAS PHY is connected, but not active
Blinking green: SAS PHY is not connected nor active