1. Connect fault domain 1 (shown in orange) to host server 1.
a. Connect a SAS cable from storage controller 1: port 1 to the first SAS HBA on host server 1.
b. Connect a SAS cable from storage controller 2: port 1 to the second SAS HBA host server 1.
2. Connect fault domain 2 (shown in blue) to host server 2.
a. Connect a SAS cable from storage controller 1: port 2 to the first SAS HBA on host server 2.
b. Connect a SAS cable from storage controller 2: port 2 to the second SAS HBA on host server 2.
3. Connect fault domain 3 (shown in gray) to host server 3.
a. Connect a SAS cable from storage controller 1: port 3 to the first SAS HBA on host server 3.
b. Connect a SAS cable from storage controller 2: port 3 to the second SAS HBA on host server 3.
4. Connect fault domain 4 (shown in red) to host server 4.
a. Connect a SAS cable from storage controller 1: port 4 to the first SAS HBA on host server 4.
b. Connect a SAS cable from storage controller 2: port 4 to the second SAS HBA on host server 4.
Example
Figure 62. Storage System with Dual 12 Gb SAS Storage Controllers Connected to Four Host Servers
1. Server 1 2. Server 2
3. Server 3 4. Server 4
5. Storage system 6. Storage controller 1
7. Storage controller 2
Next steps