a. Connect the management port on storage controller 1 to Ethernet switch 1.
b. Connect the management port on storage controller 2 to Ethernet switch 1.
4. Connect embedded fault domain 2 (shown in blue) to iSCSI network 2.
a. Connect the replication port on storage controller 1 to Ethernet switch 2.
b. Connect the replication port on storage controller 2 to Ethernet switch 2.
Figure 71. Two iSCSI Networks using the Embedded Ethernet Ports on Dual Fibre Channel Storage
Controllers
1. Corporate/management network 2. Server 1 (FC)
3. Server 2 (iSCSI) 4. FC Switch 1 (fault domain 1 for FC
fabric)
5. FC Switch 2 (fault domain 2 for FC fabric) 6. Ethernet switch 1 (fault domain 1)
7. Ethernet switch 2 (fault domain 2) 8. Storage system
9. Storage controller 1 10. Storage controller 2
5. To configure the fault domains and ports using, see the Dell Storage Client Administrator’s Guide.
Next steps
Install or enable MPIO on the host servers.
NOTE: For the latest best practices, see the Dell Storage Center Best Practices document on the
Dell TechCenter site (http://en.community.dell.com/techcenter/storage/).