YDT-35 Operating and Servicing Manual
10 HL066(EN) ISSUE 1, 05/2015
Keep hands and the body away from fluid sprays, especially injectors, leaking high
pressure pipes and seals. High pressure injection through the skin can result in fatal
injury. In the event of injection into the skin, seek urgent medical attention. Refer to the
Health & Safety Data Sheets.
Ensure that the servicing requirements and intervals as set out in the Maintenance
section are adhered to. Operate and service this equipment only if competent to do so.
Carry out regular inspections to make sure all high pressure connections are tight and
safe.
Ensure good levels of lighting for safe, efficient equipment operation.
CAUTION
This equipment contains electrostatic sensitive devices. Observe the necessary
precautions for handling electrostatic discharge sensitive devices. Do not touch printed
circuit boards and associated electronic connections and components.
Severe injury can be caused by slipping on spilt oils or fluids. All spillages of fluids in
the test area must be dealt with immediately. These can be mopped up and mineral
absorbent material spread over the affected area.
Arc welding equipment must not be operated within 5 metres of the kit. The electrical
supply to welding equipment must be provided from a remote isolating transformer. Arc
welding can disturb the electronics.
Accidents can occur to unauthorised personnel during testing. Untrained person(s)
must not be present in the test area when the equipment is operating. Only qualified
personnel are to operate this equipment.
There must be no naked flames. Potentially flammable vapours are present in the
equipment and ignition is possible although unlikely. Smoking in the vicinity of the
equipment is strictly forbidden.
Use fluid of the correct specification only. Obtain the manufacturers Health & Safety
Data Sheets and follow the advice given therein. Prolonged and repeated contact with
oil products, ingestion or excessive and prolonged inhalation of oil mists can be
detrimental to health. Use an appropriate barrier cream.
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.