EasyManua.ls Logo

Delta ASD-A2R-0421 Series - Page 312

Delta ASD-A2R-0421 Series
660 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 ParametersASDA-A2R Series
8-80 Revision December, 2014
P1-77 Reserved
Address: 019AH
019BH
P1-78 Reserved
Address: 019CH
019DH
P1-79 Reserved
Address: 019EH
019FH
P1-80 Reserved
Address: 01A0H
01A1H
P1-81 VCM2
Max. Speed of 2
n
d
Analog Speed
Command
Address: 01A2H
01A3H
Operational
Interface
Panel / Software Communication
Related Section:
P1-40
Default
Motor rated speed
Control
Mode
S/T
Unit
rpm/10V
Range
0 ~ 50000
Data Size
32bit
Format
DEC
Settings
Please refer to the description of P1-40.
P1-82 VCMLPF
Filter Switching Time between P1-40 and
P1-81
Address: 01A4H
01A5H
Operational
Interface
Panel / Software Communication
Related Section:
Default
0
Control
Mode
S
Unit
msec
Range
0 ~ 1000 (0: disable this function)
Data Size
16bit
Format
DEC
Settings
0: Disabled

Table of Contents