Chapter 8 ParametersASDA-A2R Series
8-126 Revision December, 2014
P4-xx Diagnosis Parameters
P4-00
ASH1 Fault Record (N)
Address: 0400H
0401H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32bit
Format
HEX
Settings
The last abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to
CANopen
P4-01
ASH2 Fault Record (N-1)
Address: 0402H
0403H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32bit
Format
HEX
Settings
The last second abnormal status record
Low word: LXXXX: display ALM number
High word word: hYYYY: display the error code corresponds to
CANopen
P4-02
ASH3 Fault Record (N-2)
Address: 0404H
0405H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0

Table of Contents