Chapter 8 ParametersASDA-A2R Series
8-134 Revision December, 2014
P4-16 COF2
Current Detector (V2 Phase) Offset
Adjustment
Address: 0420H
0421H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16bit
Format
DEC
Settings
Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-17 COF3
Current Detector (W1 Phase) Offset
Adjustment
Address: 0422H
0423H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16bit
Format
DEC
Settings
Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-18 COF4
Current Detector (W2 Phase) Offset
Adjustment
Address: 0424H
0425H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-