Chapter 8 ParametersASDA-A2R Series
8-146 Revision December, 2014
P5-15
PMEM
PATH#1 ~ PATH#2 No Data Retained
Setting
Address: 051EH
051FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0x0
Control
Mode
ALL
Unit
-
Range
0x0 ~ 0x0011
Data Size
16bit
Format
HEX
Settings
The parameter is divided into 00YX:
X=0: PATH#1 Data retained
X=1: PATH#1 No data retained
Y=0: PATH#2 Data retained
Y=1: PATH#2 No data retained
Others are reserved
Users can continuously write the new position into the drive
through communication by P5-05.
P5-16
AXEN Axis Position - Motor Encoder
Address: 0520H
0521H
Operational
Interface
Panel / Software Communication
Related Section:
7.3
Default
0
Control
Mode
ALL
Unit
PUU (User position unit)
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
Read: The feedback position of the motor encoder, which is the
monitor various V000 + the offset value.
Write: Any value can be written into the parameter and will neither
change V000 nor influence the positioning coordinate system. It is
only for observation when adjusting the offset value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2R-0421 Series and is the answer not in the manual?

Delta ASD-A2R-0421 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2R-0421 Series
CategoryServo Drives
LanguageEnglish

Related product manuals