EasyManua.ls Logo

Delta ASD-A2R-0421 Series - Page 390

Delta ASD-A2R-0421 Series
660 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 ParametersASDA-A2R Series
8-158 Revision December, 2014
Format
DEC
Settings
The 2
nd
Delay Time of PR mode
P5-42 DLY2
Delay Time After Position Completed
(Number #2)
Address: 0554H
0555H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
200
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16bit
Format
DEC
Settings
The 3
rd
Delay Time of PR mode
P5-43 DLY3
Delay Time After Position Completed
(Number #3)
Address: 0556H
0557H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
400
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16bit
Format
DEC
Settings
The 4
th
Delay Time of PR mode
P5-44 DLY4
Delay Time After Position Completed
(Number #4)
Address: 0558H
0559H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
500
Control
Mode
PR
Unit
ms

Table of Contents