Chapter 10 TroubleshootingASDA-A2R Series
10-36 Revision December, 2014
Feedback position counter
overflows
NMT: Reset node or 0x6040.Fault Reset
Servo Off error
NMT: Reset node or 0x6040.Fault Reset
CANopen fails to
synchronize
NMT: Reset node or 0x6040.Fault Reset
The synchronized signal of
CANopen is sent too fast
NMT: Reset node or 0x6040.Fault Reset
The synchronized signal of
CANopen is sent too slow
NMT: Reset node or 0x6040.Fault Reset
CANopen IP command is
failed
NMT: Reset node or 0x6040.Fault Reset
SYNC Period is in error
NMT: Reset node or 0x6040.Fault Reset
Position Deviation Alarm
DI:Alm Reset or P0-01 = 0

Table of Contents