Chapter 16 PLC Function ApplicationsC2000 Plus
16-140
RXPDO
PDO4 (Torque) PDO3 (Position) PDO2 (Remote I/O) PDO1 (Speed)
Description Special D Description Special D Description Special D Description Special D
Mode word D2009+100*n Mode word D2009+100*n Slave device DI D2026+100*n Mode word D2009+100*n
Actual torque D2018+100*n
Actual position
D2022+100*n
D2023+100*n
Slave device AI1 D2028+100*n
Actual frequency D2013+100*n
Actual mode D2011+100*n Actual mode D2011+100*n Slave device AI2 D2029+100*n
Slave device AI3 D2030+100*n
Because usage requires only simple to open the corresponding PDO, where TXPDO employs
D2034+100*n settings and RXPDO employs D2067+100*n settings.
These two special D areas are defined as follows:
PDO4 PDO3 PDO2 PDO1
Default
definition
Torque Position Remote I/O Speed
bit 15 14–12 11 10–8 7 6–4 3 2–0
Definition En Length En Length En Length En Length
En: indicates whether PDO is used
Length: indicates mapping of several variables
In a simple example, if we want to control a C2000 Plus slave device and make it to operate in
speed mode, we only have to make the following settings:
D2034+100*n =000Ah
Length:
TX PDO
PDO4 PDO3 PDO2 PDO1
Description Special D Description Special D Description Special D Description Special D
1 Controller
Word
D2008+100*n Controller
Word
D2008+100*n Slave
device DO
D2027+100*n Controller
Word
D2008+100*n
2 Target
torque
D2017+100*n Target D2020+100*n
D2021+100*n
Slave
device
AO1
D2031+100*n Target
speed
D2012+100*n
3 Control
method
D2010+100*n Control
method
D2010+100*n Slave
device
AO2
D2032+100*n
4
Slave device
AO3
D2033+100*n
PDO4 PDO3 PDO2 PDO1
Definition Torque Position Remote I/O Speed
bit 15 14–12 11 10–8 7 6–4 3 2–0
Definition 0 0 0 0 0 0 1 2
D2067+100*n =000Ah
Length:
TX PDO
PDO4 PDO3 PDO2 PDO1
Description Special D Description Special D Description Special D Description Special D
1 Controller
Word
D2009+100*n Controller
Word
D2009+100*n Slave
device DI
D2026+100*n Controller
Word
D2009+100*n
2 Actual
torque
D2018+100*n Actual
position
D2022+100*n
D2023+100*n
Slave
device AI1
D2028+100*n Actual
frequency
D2013+100*n
3 Actual
mode
D2011+100*n Actual
mode
D2011+100*n Slave
device AI2
D2029+100*n
4
Slave device
AI3
D2030+100*n
PDO4 PDO3 PDO2 PDO1
Definition Torque Position Remote I/O Speed
bit 15 14–12 11 10–8 7 6–4 3 2–0
Definition 0 0 0 0 0 0 1 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)