7. Place 4 screws (M10) through Fixture 1 & 2 and the plate then tighten the screws. (as shown in the
figure below)
Frame D0/D M10*4
Screw torque: 200–240 kg-cm / (173.6–208.3 Ib-in.) / (19.6–235 Nm)
Frame E M12*4
Screw torque: 300–400 kg-cm / (260–347 Ib-in.) / (29.4–39.2 Nm)
Figure 7-221

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)