EasyManuals Logo

Delta C2000 Plus Series User Manual

Delta C2000 Plus Series
1259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #778 background imageLoading...
Page #778 background image
Chapter 12 Description of Parameter SettingsC2000 Plus
12.2-23
Parameter Description Unit Default Settings
05-07
Rotor resistance (Rr) for induction
motor 1 (Ω)
Ω 0.000 0.000–65.535
05-08
Magnetizing inductance (Lm) for
induction motor 1 (mH)
mH 0.0 0.0–6553.5
05-09
Stator inductance (Lx) for induction
motor 1 (mH)
mH 0.0 0.0–6553.5
10-25
FOC bandwidth for speed
observer
Hz 40.0 20.0–100.0
11-00 System control 513 0–65535
11-01 Per unit of system inertia pu 256 1–65535
11-02 ASR1 / ASR2 switch frequency Hz 7.00 5.00–599.00
11-03 ASR1 low-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)
11-04 ASR2 high-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)
11-05 Zero-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
AltitudeUp to 1000m without derating
CommunicationCANopen
Output Current2.5A
Protection FeaturesOvercurrent, Overvoltage, Overtemperature
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity95% RH (non-condensing)