EasyManuals Logo
Home>Delta>DC Drives>C2000 Plus Series

Delta C2000 Plus Series User Manual

Delta C2000 Plus Series
1259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #859 background imageLoading...
Page #859 background image
Chapter 13 Warning CodesC2000 Plus
13-58
ID No. Display on LCD Keypad Warning Name Description
66
CAN/M SDO time-out
(PCSd)
CANopen Master SDO time-out
Action and Reset
Action condition
When the CANopen master sends a SDO
command, and the BUS is too busy to
transmit the command, PCSd warning displays.
Action time Immediately displays when the fault is detected
Warning setting parameter N/A
Reset method The warning automatically clears when the SDO transmits normally.
Reset condition N/A
Record N/A
Cause Corrective Actions
When the CANopen master
transmits a SDO command, and
does not receive feedback from
the Slave within 1 sec.
Check if the Slave responds within 1 second.