Chapter 13 Warning CodesC2000 Plus
13-64
ID No. Display on LCD Keypad Warning Name Description
73
ExCom Bus off
(ECbF)
The c
ommunication card detects too much errors in the
BUS, then enters the BUS-OFF status
and stop
communicating
Action and Reset
Action condition When the drive detects BUS-off (for DeviceNet)
Action time Immediately acts
Warning setting parameter N/A
Reset method Cycle the power
Reset condition N/A
Record N/A
Cause Corrective Actions
Poor connection of the cable Re-connect the cable
Bad quality of the cable Replace the cable