Chapter 13 Warning CodesC2000 Plus
13-66
ID No. Display on LCD Keypad Warning Name Description
75
ExCom factory defect
(ECFF)
Factory default setting error
Action and Reset
Action condition Factory default setting error
Action time Immediately acts
Warning setting parameter N/A
Reset method Cycle the power
Reset condition N/A
Record N/A
Cause Corrective Actions
Factory default setting error Use DCISoft to reset to the default value.