Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-31
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
25
Interrupt error
(INTR)
MCU overload and causing the control circuit
interruption error
Action and Reset
Action condition N/A
Action time
Act immediately
Fault treatment parameter
N/A
Reset method
Manual reset
Reset condition
N/A
Record
Yes
Cause
Corrective Actions
PWM carrier is set too high to
calculate the control calculation
Decrease the carrier setting