6. Communication Warning / Fault Table
6.1 Motor drive warning / fault table
ID No.
Warning /
Fault / Code
Warning / Fault
Name
Description Corrective Action
81 ECto_WARN
EtherCAT
communication time
out
Timer out warning on the
Communication between
communication card and the
host controller.
-Verify if communication
system is wiring correctly.
-Verify if the upperhost is
connecting correctly.
89 ECCb_WARN
Communication
card disconnected
Warning on the disconnected
communication card
-Reinstall the communication
card.
-Change a new
communication card or
change a new motor drive.
111 SYCE_WARN
Synchronization
warning
The source of communication
is not the communication
card. Loss of synchronization
signal (data packet) after
setting up the synchronization
mode. A warning message
pops up.
-Reinstall a motor drive to the
upperhost.
161 SYCE_ERR
Synchronization
fault
The source of command is the
communication card. Loss of
synchronization signal (data
packet) after setting up the
synchronization mode. A fault
message pops up.
Reinstall a motor drive to the
upperhost.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com