A.3.3 OD 6000h Communication Object Group
Object 6007h:Abort connection option code
Abort connection option code
No
Setting Range
2: Switch on Disable
When object 6007h = 0, CANopen ignores a disconnection fault, no warning and do nothing.
When object 6007h =2, CANopen turns to Switch on Disable and displays ECto. CANopen then
follows the setting at object 605Ah to trigger parking. When reconnection is successful, the warning
code disappears.
When object 6007h = 3, CANopen turns to Quick Stop and displays ECto. CANopen then follows
the set=ting at object 605Ch to trigger parking. When reconnection is successful, the warning code
clears.
Object 603Fh:Error code
Yes
Object 6040h:Controlword
Yes