DVS Series Managed Industrial Ethernet Switches User’s Manual
System Eve
nts
Description Factory Default
Power 1
Specify the power event status:
Disable: Disable Power 1 to trigger relay alarm 1 or 2.
On to Off: When the status of Power 1 changes from On to Off,
relay alarm 1 or 2 is triggered.
Off to On: When the status of Power 1 changes from Off to On,
relay alarm 1 or 2 is triggered.
Disable
Power 2
Specify the power event status:
Disable: Disable Power 2 to trigger relay alarm 1or 2.
On to Off: When the status of Power 2 changes from On to Off,
relay alarm 1 or 2 is triggered.
Off to On: When the status of Power 2 changes from Off to On,
relay alarm 1 or 2 is triggered.
Disable
DI 1
Specify the DI event status:
Disable: Disable DI 1 to trigger relay alarm 1 or 2.
On to Off: When the status of DI 2 changes from On to Off, relay
alarm 1 or 2 is triggered.
Off to On: When the status of DI 2 changes from Off to On, relay
alarm 1 or 2 is triggered.