3-8
  Set the Parameter 01-00 = 3 
Control mode 
Setting value   
of Parameter 
01-00 
0: VF 
1: Reserved 
2: Reserved 
3: FOC vector control + Encoder (FOCPG) 
4: Reserved 
5: FOCPM 
6: Reserved 
  Test run 
When the motor is in a no-load state, the speed command is set to 10 rpm for low-speed test 
run. Make sure that the output current value is close to the no-load current.   
If no error occurs, gradually increase the value of speed command to the highest speed.   
  Make sure that the pump’s oil supply direction is the forward direction of the motor.   
Synchronous motor 
  Set the Parameter 01-00 = 5 
Control mode 
Setting value   
of Parameter 
01-00 
0: VF 
1: Reserved 
2: Reserved 
3: FOC vector control + Encoder (FOCPG) 
4: Reserved 
5: FOCPM 
6: Reserved 
  Set the Parameter 01-26 = 3 
Encode type 
Setting value   
of Parameter 
01-26 
0: ABZ 
1: ABZ+HALL (only used for Delta’s servo motors) 
2: ABZ+HALL 
3:Resolver 
  Set the Parameter 01-29 
Number of pulses for each revolution of the encoder 
Setting value   
of Parameter 
01-29 
1~20000