EasyManua.ls Logo

Denon RCD-M40 - 4.7. Displaying the laser current; 4.7.1. Overwriting the stored data

Denon RCD-M40
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
(2) "
2
" button to return to "4. CD TEST MODE (1)".
※ If you have not completed the adjustment, the displayed values are not correct.
4.7. Displaying the laser current
(1) Press and hold the "
2
" button for at least one second while stopped (during the display in "4. CD TEST MODE (1)") to
turn the laser on and measure the laser current.
"
13
"
S / C : X X m A / Y Y m A
L A S E R C U R R E N T
(
13
blinks/XX:Stored data (stored EEPROM value))
The initial current value is measured after the laser has been on for three seconds.
The current value is updated every 3 seconds.
The laser on current is measured using A/D conversion. Figures below decimal point are omitted.
(2) "
2
" button to return to "4. CD TEST MODE (1)".
※ Stored data is not erased when the unit is initialized (cold start mode).
4.7.1. Overwriting the stored data
(1) With the laser current displayed, press and hold the "
1
/
3
" button for over 5 second to save the current value on
EEPROM (overwrite the stored data).
"
13
"
S T O R E D
L A S E R C U R R E N T
(
13
ashes)
(2) Press the "
1
/
3
" button to save the initial value to the EEPROM.
(3) After overwriting, the 4.7(1) appears again.
※ Rewriting is performed upon shipment from the factory and when the mechanism is replaced.