6. Accumulated laser on time display mode
(1) While holding down buttons the "
X
" and "
2
" buttons simultaneously, insert the AC plug to turn the power on.
X X X X X h o u r
L A S E R O N T I M E
• The laser drive time is added and the result is displayed.
• Each count is 10 minutes (truncated if less than 10 minutes).
• The count value is saved to the EEPROM.
• The accumulated laser on time is displayed in hours.
• The count value is not erased when the unit is initialized (3. Cold start mode).
• Minimum display specication (also possible when the display time below is exceeded).
• Number of digits retained in EPROM : 4 digits, 0xFFFF
• Number of digits displayed : 5 digits
• When 10922 hours are exceeded, the retained data is not updated and the value is xed as 0xFFFF (the display is
xed as "10922 hour").
(2) To exit this mode, unplug the power cord.
6.1. Resetting the count value
(1) With the accumulated laser-on time displayed, press and hold the "
1
/
3
" button for over 5 second to reset the count
value (overwrite the stored data).
C L E A R
L A S E R O N T I M E
(2) After initialization is completed, the unit returns to the display in "6. Accumulated laser on time display mode (1)" (top:
"00000 hour").
※ The Count value is reset upon shipment from the factory and when the mechanism is replaced.
7. Updating MAIN u-COM
(1) Turn the power on.
(2) Switch SOURCE to iPod/USB.
(3) Connect the USB memory device on which the program is written.
(4) Press and hold "
2
" for ve seconds or more.
(5)-1 Press "
+/
9
" (to start the update).
(5)-2 Press "
8
/-
" (to exit the update).
【Display when searching for update le】
S e a r c h i n g U S B
【Display when starting/exiting the update】
S t a r t U p d a t e
E x i t / C o n t i n u e
【Display during update】
M C U U p d a t i n g