51
Code128, EAN-128
Items Parameters Defaults Refer to:
Enable √
Scanning Code 128
Disable
Enable √
Scanning EAN-128
Disable
Minimum number of digits readable
for Code 128 and EAN-128
1 digit
Maximum number of digits readable
for Code 128 and EAN-128
1 to 99 digits
(excluding 1-digit C/D)
99 digits
(See Note 3.)
Transmit after conversion to GS √
Transmission of FNC1 for Code 128 and
EAN-128
Disable
Section 11.3 (5)
MSI, Plessey
Items Parameters Defaults Refer to:
Enable
Scanning MSI
Disable √
Minimum number of digits readable for MSI 3 digits
Maximum number of digits readable for MSI
3 to 99 digits
(including 2-digit C/D)
99 digits
(See Note 3.)
Enable
Scanning Plessey
Disable √
Minimum number of digits readable
for Plessey
4 digits
Maximum number of digits readable
for Plessey
4 to 99 digits
(including 2-digit C/D)
99 digits
(See Note 3.)
(Note 3) The setting range does not mean the number of digits that the scanner can read.
: Can be changed only with the configuration software.