50
Item Parameters Defaults Refer to:
MOD-16 √
Check digit method for Codabar (NW-7)
7-check method
Transmit a/b/c/d
Transmit A/B/C/D
Transmission of start/stop codes
for Codabar (NW-7)
Disable √
Section 11.3 (5)
Code 39
Item Parameters Defaults Refer to:
Enable, without C/D √
Enable, with C/D
Scanning Code 39
Disable
Minimum number of digits readable
for Code 39
1 digit
Maximum number of digits readable
for Code 39
1 to 99 digits
(excluding start/stop codes)
99 digits
(See Note 3.)
Enable √
Transmission of a check digit for Code 39
Disable
Section 11.3 (5)
(See Note 4.)
Enable
Transmission of start/stop codes for Code 39
Disable √
Enable
Conversion to Full ASCII for Code 39
Disable √
Section 11.3 (5)
Code 93
Items Parameters Defaults Refer to:
Enable
Scanning Code 93
Disable √
Minimum number of digits readable
for Code 93
1 digit
Maximum number of digits readable
for Code 93
1 to 99 digits
(excluding start/stop codes and 2-digit
C/D)
99 digits
(See Note 3.)
(Note 3) The setting range does not mean the number of digits that the scanner can read.
(Note 4) To enable the transmission of a check digit, it is also necessary to select the "Enable, with C/D" parameter.