6159924330 - 08/2020 - 53 -
Creating a Pset in CVI CONFIG
Launch CVI CONFIG from the launchbar on the computer desktop.
Click the icon Scan.
In the column Action, click Add to a working area.
In the next screen, click OK and click Exit when the transfer is done.
See that the controller has been added in the working area.
Values are already present as the software has uploaded all tools characteristics.
Tightening unit 1 is driving Tool 1 (cord tool), tightening unit 51 is driving Tool 51 (cordless tool).
Go to the Tree view area, expand Tightening unit - 1 and click Psets.
Right-click Psets, add a Pset and click OK.
Select "Simple mode".
Change the target torque to 5 Nm.
Click OK to validate.
Use the mouse to point and click this box in the middle pane.
Click this icon to update the product.
If you get the message Invalid Pset settings in the controller, go to CVI CONFIG, adjust torque and angle val-
ues in the step Tightening and transfer the configuration again into the controller.
Go to the controller display.
0
Tap this icon to select the Pset.
Click this icon to validate.
Pset 1 is displayed.
Press the trigger of tool 1 to run the Pset.
The result is displayed on the controller screen.