LCC_LCD1-16/51 Oven Owner’s Manual C244, 320207, REV B
37 of 82
Figure 11. LCC/LCD Oven Utility Connections.
5.2.2.1. Nitrogen with Water-Cooled Models
1. Connect nitrogen supply line to NITROGEN INLET on the rear right of the
oven (Figure 11).
Nitrogen pressure supplied should run at 70 psi (4.83 bar) but not
more than 80 psi (5.52 bar). Check for leaks.
2. Install water connection for cooling coils to WATER INLET (Figure 11).Verify
the valve on the flowmeter is turned OFF, that is, fully clockwise.
Water pressure supplied to the oven must not exceed 100 psi (6.89
bar). Despatch recommends installing a regulator to prevent
surging.
3. Check for leaks by slowly opening the valve on the flowmeter and allowing
any air to bleed out.
Nitrogen inlet
Water inlet
Flow-meter valve
Water outlet
Water drain