3300-0188-0M Rev L y apex Digital Scale Owner’s 27
9< (Gravity Compensation)
Gravity compensation accounts for latitudes and elevations that are different from where the
scale was calibrated. In order to calculate the value for this parameter, use the gravitational
constant of the location where the scale was calibrated divided by the gravitational constant
of where the scale will be installed:
Gravitational Constant (Calibration location)
---------------------------------------------------------- = value
Gravitational Constant (Operation location)
This should give you a value close to 1 that you can enter in to compensate for variation in
gravity due to elevation/latitude.
The display will show 9< and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to select a new value and then press
the key to save it and proceed to the next prompt.
Allowable values for 9< are 0.000 to 2.000.
NOTE: The default value is 1.000, which means there is no gravity compensation.
&($ (Scale Model)
The display will show ;($ and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to toggle the Scale Model between
$i (apex®) or '*; (custom, not applicable at this time) and then press the
key to
save it. You will be returned to the $ prompt, the current Scale Capacity setting.
This will change the default settings and operation of the scale. For instance, select $i
for type in order to use the stand-up type scale for the scale with the inline height rod or
sonar height rod.
Allowable settings are $i or '*;.
NOTE: If your scale is the model apex-C or apex-sh-C (equipped with the Redbird
Wi-Fi and Bluetooth (BLE) wireless transmitter), additional setup prompts will be
shown after selecting the ;($ setting.
Refer to the Setup and Operation Manual for apex® Clinical Scales with Wi-Fi and
Bluetooth (3300-0320-0M), for guidance through setup and operation of the apex
Wi-Fi and Bluetooth (BLE) wireless transmitter features. Otherwise, setup and
calibration is complete.
Setup and Calibration is Complete
The setup and calibration process have been completed. Press the key to turn the scale off
and then press it again to turn the scale back on. The scale is now ready for normal operation.