DIMAX804KC User’s Manual
40
DEXON Systems
CLEAR_LAYOUT
clear_layout - Request
Request message:
<clear_layout id="n" needack="{Yes|No}"/>
Description:
The clear_layoutt request is used to remove the information stored in the layout identified by id.
Attributes:
• id: layout identifier
RECALL_LAYOUT
recall_layout - Request
Request message:
<recall_layout id="n" needack="{Yes|No}"/>
Description:
The recall_layout request is used to set the arrangement stored in the layout identified by id to
the DIMAX device.
Attributes:
• id: layout identifier
SAVE_LAYOUTS
save_layouts - Request
Request message:
<save_layouts/>
Description:
The save_layouts request is used to query the whole layout configuration in order to save it for
future loading. This request is available only for clients with administrator privilege.
save_layouts - Reply
Reply message:
<save_layouts>
...
</save_layouts>
Description:
The DIMAX server sends save_layouts reply message to the client in response to the
save_layouts request.