DIMAX804KC User’s Manual
DEXON Systems
41
LOAD_LAYOUTS
load_layouts - Request
Request message:
<load_layouts needack="{Yes|No}" >
...
</load_layouts>
Description:
The load_layouts request is used to load the whole layout configuration information previously
saved with the help of save_layouts message. This request is available only for clients with
administrator privilege.
4.2.6
Preset
QUERY_PRESET_STATUS
query_preset_status - Request
Request message:
<query_preset_status />
Description:
The query_preset_status request is used to obtain configuration information on preset
parameters.
preset_status - Reply
Reply message:
<preset_status>
<preset id="n" name="x" active="{No|Yes}">{Empty|Used}</preset>
...
</preset_status>
Description:
The DIMAX server sends preset_status reply message to the client in response to the
query_preset_status request.
The DIMAX server sends preset_status event message to the client if the states of one or more
presets have been changed.
Attributes:
id: preset identifier
name: preset name
active: shows that the preset is currently active or not
Value:
Empty: the preset identified by id is not in use, i.e. does not store any information