DIMAX804KC User’s Manual
46
DEXON Systems
Description:
The DIMAX server sends hardware_monitor_status reply message to the client in response to
the query_hardware_monitor_status request.
Elements:
temperature: the currently measured value received from temperature sensor. The
sensor is identified by source attribute, the range of valid values is specified by min and
max attributes. The measuring unit is also specified.
tachometer: the currently measured speed received from an internal fan. The fan is
identified by source attribute, the minimum speed is specified by min attribute.
ECHO
echo - Request
Request message:
<echo>message_content</echo>
Description:
In response to the echo request the DIMAX server echoes the message_content in the echo
reply.
Reply message:
<echo>message_content</echo>
Description:
The DIMAX server sends the same echo message back to the client.
SAVE_CONFIG
save_config - Request
Request message:
<save_config/>
Description:
The save_config request is used to query the whole configuration set in order to save it for
future loading.
This request is available only for clients with administrator privilege.
save_config - Reply
Reply message:
<save_config>
...
</save_config>
Description:
The DIMAX server sends save_config reply message to the client in response to the
save_config request.