5.3. Unit Weight Operation :
5.3.1. Unit Weight Operation by Sampling :
1 Display in the weighing mode
2 Place 10 pcs of the item to be sampled on the platter.
3 Press the [PIECES] key. Please wait for a few seconds for the computation.
4 The Unit Weight Display shows the Unit Weight of the samples (1.255/1000 pieces) and the
Quantity Display shows the Quantity of the pieces i.e. 10 in this case.
Note : When the samples are placed on the platter, if the insufficient lamp is “ON”, then add
few more samples until the insufficient lamp is “OFF. Now, before pressing the [PIECES]
Key, enter the no. of samples using the key board and then press the [PIECES] Key. For e.g. :
After putting ten pieces of the sample, if the insufficient lamp is “ON”, then add few more
samples (say 3) until the insufficient lamp is “OFF”. Now using the key board, enter [1] [3] and
then press the [PIECES] Key to compute the Unit weight of the samples.
5.3.2. Unit Weight Operation by Key Entry :
This following procedure is used if the unit weight is already known.
1 Display in the weighing mode
2 Enter the known Unit Weight using the keyboard. [2][.][8][7]
3 Press the [UNIT WEIGHT] key to enter the unit weight.
4 Place 2 lb weight on the platter. The scale displays the quantity for the weight placed on the
platter.