35
Alarm In: User may set four groups of alarm inputs
Alarm Type: There are 3 types for your choice: Normally-Open, Normally-Close, and OFF.
Choose the one to match your sensor type, or Choose OFF to close the sensor trigger function.
Latch Time: you can set how long the buzzer will sound when external sensor is triggered (10s,
20s, 40s, and 60s).
Buzzer: The DVR can use its internal buzzer to emit an alarm tone. You can set the buzzer
duration in seconds when a sensor is triggered.
Post Recording: You can set how long alarm record will last when alarm ends (30s, 1minutes,
2minutes, 5minutes).
Alarm out: Tick to enable external alarm device to emit an alarm tone when a sensor is triggered.
Show Message: Display the alarm messages on the screen when sensor is triggered.
Send Email: Set to send email to specified email when sensor is triggered.
Full Screen: When sensor is triggered, the corresponding channel will be switched to the full
screen mode.
Analog Channels/IP Channels: Select which channels you want to record when sensor is
triggered.