43
Optimized layout for A4 print.
TECH_MAN_ENG_LTP
Short string
Extended string
01ST,GS, 0.0,kg<CR><LF>
where
01 Code 485 of the instrument (2 characters), only if communication mode 485 is enabled
ST Scale status (2 characters):
US - Unstable weight
ST - Stable weight
OL - Weight overload (out of range)
UL - Weight underload (out of range)
TL - Scale not level (inclinometer active)
, ASCII 044 character
GS Type of weight data (2 characters)
GS - Gross
NT - Net
, ASCII 044 character
0.0 Weight (8 characters including the decimal point)
, ASCII 044 character
kg Unit of measurement (2 characters)
<CR><LF> Transmission terminator, characters ASCII 013 and ASCII 010
011ST, 0.0,PT 20.8, 0,kg<CR><LF>
where
01 Code 485 of the instrument (2 characters), only if communication mode 485 is enabled
1 ASCII 049 character
ST Scale status (2 characters):
US - Unstable weight
ST - Stable weight
OL - Weight overload (out of range)
UL - Weight underload (out of range)
TL - Scale not level (inclinometer active)
, ASCII 044 character
, ASCII 044 character
0.0 Net weight (10 characters including the decimal point)
, ASCII 044 character
PT Indication of pre-set manual tare (2 characters)
20.8 Tare weight (10 characters including the decimal point)
, ASCII 044 character
0 Number of pieces (10 characters)
, ASCII 044 character
kg Unit of measurement (2 characters)
<CR><LF> Transmission terminator, characters ASCII 013 and ASCII 010