10 BA FlexxPump 125 - 24 V_20181121_EN de 201811
Product Description
3.2 Functional Description
The FlexxPump 125 has a double piston pump. The two pistons run in opposite directions
whereby one piston sucks in the lubricant respectively whilst the other one pumps the
quantity sucked in by the previous stroke to the outlet. 0.15 cm³ of lubricant is pumped per
displacement or metering cycle. The FlexxPump 125 is controlled by an external controller
(PLC) in the factory settings. Alternatively, the time and frequency of the lubrication and the
lubricant quantity per lubrication process can be dened by the parameters t and C.
The operating state and error messages are displayed on the LCD. In addition, statuses and
errors can be read out and interpreted by the external controller.
3.3 Technical Data
Housing
Dimensions with 125 ml cartridge (W x H x D) 83 x 152 x 83 mm
Dimensions with 250 ml cartridge (W x H x D) 83 x 190 x 83 mm
Weight (without lubricant) approx. 350 g
Assembly possibilities Rear 2x M5
Bottom 1x M5 and/or G1/4“
Torque M5 3 Nm
Installation position any, preferably vertical
Permissible operating temperature
-20 °C ... +70 °C
Material PA 6.6 GF 30 / POM
Lubricant
Cartridge lling volume
125 cm³ / 250 cm³
Lubricating medium Grease up to NLGI class 3, solid parts possible
Hydraulic data
Number of outlets 1
Outlet thread G1/4" and M6
Number of lubricating points up to 4 in connection with splitter
up to 14 in connection with progressive distributor
Hydaulic connection direct or by additional hose connection to PA hose
Max. pressure 12 or 50 bar (adjustable)
Dosing volume/stroke
0,15 cm³
Number of pump strokes per
cartridge
approx. 830 (at 125 cm³) / approx. 1,666 (at 250
cm³)
Electrical data
Display LCD
Operating voltage
24 V (20V...28V)DC (external)
Current consumptio I
max
< 300 mA
no-load current < 25 mA
Fusing 750 mA, slow-blow
Connecting plug M12x1
Protection class IP 54