20 734N Installation and Programming Guide | Digital Monitoring Products, Inc.
PANEL IP PORT
Enter the port number that the 734N uses to send communication
to the panel. This must be the same port that is programmed in the
734N Listen Port in Network Options programming of the panel. The
panel IP port cannot be the same as the panel network programming
port. Default is 2002.
734N PASSPHRASE
You must enter an 8-16 character alphanumeric passphrase to encrypt
communication with the panel. The 734N passphrase must match the
734N passphrase entered in Network Options programming of the
panel. The passphrase is blank by default.
ACCESS OPTIONS
Press any select key or area to enter the Access Options menu. Press
CMD to advance to the Stop options. Press the back arrow to display
the Communication menu.
PANEL IP PORT
2002
734N PASSPHRASE
734N
ACCESS OPTIONS