2 734N Installation and Programming Guide | Digital Monitoring Products, Inc.
FORM C RELAY
The 734N’s Form C relay draws up to 35 mA of current. See NC/C/NO (Dry Contact Relay) and
Isolation Relay for more information.
PROGRAMMING CONNECTION
The 734N also provides a keypad programming connection that allows you to use a standard DMP
LCD keypad for initial setup. Programming can be completed using a keypad connected to the 734N
or from an XR150/XR550 or XR150INT/XR550INT panel.