Digital Monitoring Products, Inc. | 7800 Series Installation and Programming Guide 11
Wire the Electronic Lock
7873/7873H keypads provide a Form C (SPDT) relay for controlling locks and other
electronically-controlled barriers. The Form C relay draws up to 15mA of current and
the contacts are rated for 1Amp at 30VDC maximum, resistive. The wires marked NO
C NC allow you to connect the device wiring to the relay for module control. Use an
additional power supply to power magnetic locks and door strikes. See Figure 8 and
Figure 9.
Wire the 333 Suppressor
Use the included 333 suppressor with the keypad to suppress any surges caused
by energizing a magnetic lock or door strike. Install the 333 across the keypad C
(common) and NO (normally open) or NC (normally closed) wires.
If the device being controlled by the relay is connected to the NO and C wires, install
the suppressor on the NO and C wires. Conversely, if the device is connected to the
NC and C wires, install the 333 Suppressor on NC and C wires. See Figure 8 and
Figure 9.
4
5

Other manuals for DMP Electronics 7800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 7800 Series and is the answer not in the manual?

DMP Electronics 7800 Series Specifications

General IconGeneral
BrandDMP Electronics
Model7800 Series
CategoryKeypad
LanguageEnglish

Related product manuals