20 7800 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
Zone 2 Bypass Time
Enter the number of bypass seconds to elapse before the
bypass timer expires. Range is 20-250 seconds. Press any
select area to clear the keypad display and enter the number
of seconds. Default is 40 seconds.
Relock on Zone 2 Change
Select NO (default) to leave the relay on when Zone 2 changes
to an open or short condition during bypass. Select YES to
turn the relay o when Zone 2 changes to open or short
during bypass.
ZONE 2 BYPASS
TIME: 40
System Armed
TODAY
WEDNESDAY
82
98 77
CURRENT
HI LO
85 68
HI LO
98 77
Panic
Chime
Reset
Favorites
ARMED
5 Second
Strike
40-Second Zone 2 Bypass
entry/exit timer.
10 seconds before
the bypass time expires,
the device beeps if
the door is still open.
End of
timer.
40
Seconds
A zone open/short is
indicated if the door
remains open.
Figure 11: Zone 2 Bypass Timeline
RELOCK ON ZONE 2
CHANGE? NO YES

Other manuals for DMP Electronics 7800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 7800 Series and is the answer not in the manual?

DMP Electronics 7800 Series Specifications

General IconGeneral
BrandDMP Electronics
Model7800 Series
CategoryKeypad
LanguageEnglish

Related product manuals